Sable car GAZ-2752, 2217, 2310>> Electric equipment>> Control devices>> Check of control devices and sensors>> Voltmeter

Voltmeter

 PERFORMANCE ORDER

The voltmeter can be checked, comparing its indications to tester indications. Before carrying out test we recommend to take the voltmeter energized 12 about 5 minutes.
The failed control devices it is replaced, for what …

… By a shlitsevy screw-driver it is turned on eight саморезов.

We remove a frame with glass.

Head «on 5,5» we turn on nuts of fastening of the faulty control device.

We take out the device.

We establish the new device in a combination of devices in return sequence.